Beskrivelse
Vötsch
Model: VCL 7003
Air-cooled climate test chamber
Hnsdpfxsv Tnd Ss Aatsu
Test chamber volume: approx. 34 liters
Specifications for temperature tests:
Temperature range: -70 to +180°C
Temporal temperature deviation: ±0.3 to ±1.0 K
Spatial temperature uniformity: ±0.5 to ±2.0 K
Temperature change rate (heating): 4.0 K/min
Temperature change rate (cooling): 3.0 K/min
Heat compensation max: 550 W
Temperature calibration values: +23°C and +80°C
Specifications for climate tests:
Temperature range: +10 to +95°C
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Temporal temperature deviation: ±0.3 to ±0.5 K
Spatial temperature uniformity: ±0.5 to ±1.5 K
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 350 mm, Depth 300 mm, Height 310 mm
External dimensions: Width 640 mm, Depth 750 mm, Height 1730 mm
Electrical connection:
1/N/PE AC 230 V ±10%, 50 Hz
Rated current: 11.0 A
Max. rated power: 2.5 kW
Sound pressure level: 59 dB(A)
Refrigerant: R-404 A / R23
Weight: approx. 130 kg
For your assurance as the buyer, please note the following:
The following procedures are performed on all our chambers prior to delivery:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful inspection, the units are subject to a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Model: VCL 7003
Air-cooled climate test chamber
Hnsdpfxsv Tnd Ss Aatsu
Test chamber volume: approx. 34 liters
Specifications for temperature tests:
Temperature range: -70 to +180°C
Temporal temperature deviation: ±0.3 to ±1.0 K
Spatial temperature uniformity: ±0.5 to ±2.0 K
Temperature change rate (heating): 4.0 K/min
Temperature change rate (cooling): 3.0 K/min
Heat compensation max: 550 W
Temperature calibration values: +23°C and +80°C
Specifications for climate tests:
Temperature range: +10 to +95°C
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Temporal temperature deviation: ±0.3 to ±0.5 K
Spatial temperature uniformity: ±0.5 to ±1.5 K
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 350 mm, Depth 300 mm, Height 310 mm
External dimensions: Width 640 mm, Depth 750 mm, Height 1730 mm
Electrical connection:
1/N/PE AC 230 V ±10%, 50 Hz
Rated current: 11.0 A
Max. rated power: 2.5 kW
Sound pressure level: 59 dB(A)
Refrigerant: R-404 A / R23
Weight: approx. 130 kg
For your assurance as the buyer, please note the following:
The following procedures are performed on all our chambers prior to delivery:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful inspection, the units are subject to a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Udbyder
Bemærk: Registrer dig gratis eller log ind, for at få adgang til alle oplysninger.
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Din annonce er blevet slettet
Der opstod en fejl