Klimatestkammer med luftfugtighedWeiss -72°C bis +180°C
WK3-340/70
Klimatestkammer med luftfugtighed
Weiss -72°C bis +180°C
WK3-340/70
Stand
Brugt
Beliggenhed
Borken 

Oplysninger om maskinen
- Maskinbetegnelse:
- Klimatestkammer med luftfugtighed
- Producent:
- Weiss -72°C bis +180°C
- Model:
- WK3-340/70
- Stand:
- meget god (brugt)
Pris og placering
- Beliggenhed:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring op
Detaljer om tilbuddet
- Annonce-ID:
- A18791221
- Referencenummer:
- 24566
- Opdatering:
- sidst den 02.07.2025
Beskrivelse
Weiss
Pjdpfxsv Sr Hzs Ag Nopu
Model: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control unit: "Touch Panel"
All control and operating commands can be executed by simply touching the function symbols on the touch panel control unit.
Leveling Feet
To compensate for uneven floors and ensure sufficient ventilation of the machine compartment, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on both the right and left sides. These allow measurement cables and test devices to be routed into the test chamber.
Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test chamber dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Temperature test specifications:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temperature deviation, over time: ± 0.1 to ± 0.5 K
Temperature uniformity, spatial: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature uniformity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test chamber illumination: Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A Nominal power: 4.9 kW
Customer-provided circuit breaker: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety as a buyer, please note the following information:
The following procedures are performed in advance on our offered chambers:
1. Functional inspection and replacement of necessary components
2. If required, a new refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Annoncen er blevet oversat automatisk. Oversættelsesfejl kan forekomme.
Pjdpfxsv Sr Hzs Ag Nopu
Model: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control unit: "Touch Panel"
All control and operating commands can be executed by simply touching the function symbols on the touch panel control unit.
Leveling Feet
To compensate for uneven floors and ensure sufficient ventilation of the machine compartment, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on both the right and left sides. These allow measurement cables and test devices to be routed into the test chamber.
Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test chamber dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Temperature test specifications:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temperature deviation, over time: ± 0.1 to ± 0.5 K
Temperature uniformity, spatial: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature uniformity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test chamber illumination: Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A Nominal power: 4.9 kW
Customer-provided circuit breaker: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety as a buyer, please note the following information:
The following procedures are performed in advance on our offered chambers:
1. Functional inspection and replacement of necessary components
2. If required, a new refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Annoncen er blevet oversat automatisk. Oversættelsesfejl kan forekomme.
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Du kan også være interesseret i disse annoncer.
Annoncer
Tyskland
603 km
Bearbejdningscenter - lodret
HEDELIUSBC 100/50-2500
HEDELIUSBC 100/50-2500
Annoncer
Tyskland
769 km
KEYENCE IM-8020
KEYENCEIM-8020
KEYENCEIM-8020
Annoncer
Sremska Mitrovica
1.441 km
Kun lydisoleret kabine
for BRUDERER pressesSound insulating cabin
for BRUDERER pressesSound insulating cabin
Annoncer
Kassel
551 km
Tryk på
Massey Ferguson4160 V Protec 25 Messer
Massey Ferguson4160 V Protec 25 Messer
Annoncer
La Grand-Croix
1.247 km
Stanglader LNS
LNS
LNS
Annoncer
Contamine-sur-Arve
1.149 km
Cnc multispindel automatisk drejebænk
INDEXMS 32 B
INDEXMS 32 B
Annoncer
Hilzingen
948 km
Bruderer BSTA 110
BRUDERERBSTA 110
BRUDERERBSTA 110
Annoncer
Sonsbeck
557 km
Universalprøvemaskine Trækprøvemaskine
Hegewald & PeschkeH2,5TMNI
Hegewald & PeschkeH2,5TMNI
Annoncer
Ciriè
1.236 km
Hurtig dobbeltkolonnepresse
YAMADA DOBYNXT-60
YAMADA DOBYNXT-60
Annoncer
BORNEM
671 km
Kassevogn
FiatDoblò F5036 Cargo Van L1 Heavy – 50 kWh – Elekt...
FiatDoblò F5036 Cargo Van L1 Heavy – 50 kWh – Elekt...
Din annonce er blevet slettet
Der opstod en fejl