Klimaskab med fugt, 34 literWeiss
WKL 34/60 -60°C bis 150°C
Klimaskab med fugt, 34 liter
Weiss
WKL 34/60 -60°C bis 150°C
Stand
Brugt
Beliggenhed
Borken 

Oplysninger om maskinen
Pris og placering
- Beliggenhed:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring op
Detaljer om tilbuddet
- Annonce-ID:
- A22199292
- Referencenummer:
- 24134
- Opdatering:
- sidst den 24.06.2026
Beskrivelse
Weiss
Model: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
Temperature range: -60°C to +150°C
Chamber volume: 34 liters
Standard pass-throughs included:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for temperature testing:
Temperature range: -60°C to +150°C
Temperature deviations at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at working space center: ±0.3 to ±1 K, ±1 to ±2 K
Spatial temperature variation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Specifications for climate testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature and humidity deviations at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at working space center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K (temperature gradient): 1 to 3
Temporal humidity fluctuation at working space center: ±3 to ±5% RH
Operating data:
Chamber lighting: Halogen bulb 12V, 20W
Nominal voltage: 1/N / PE AC 230 V ±10% 50 Hz
Nominal power: 2.5 kW
Nominal current: 11 A
On-site fuse: 16A slow-blow
Heat emission (air-cooled chambers):
Klodpfx Aszgr U Rsb Iow
Max. heat emission to environment: 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally approved refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Amendments and errors in the technical data and specifications reserved!)
For further questions, please contact us by phone.
Annoncen er blevet oversat automatisk. Oversættelsesfejl kan forekomme.
Model: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
Temperature range: -60°C to +150°C
Chamber volume: 34 liters
Standard pass-throughs included:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for temperature testing:
Temperature range: -60°C to +150°C
Temperature deviations at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at working space center: ±0.3 to ±1 K, ±1 to ±2 K
Spatial temperature variation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Specifications for climate testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature and humidity deviations at steady state (per IEC 60068-3-5):
Temporal temperature fluctuation at working space center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K (temperature gradient): 1 to 3
Temporal humidity fluctuation at working space center: ±3 to ±5% RH
Operating data:
Chamber lighting: Halogen bulb 12V, 20W
Nominal voltage: 1/N / PE AC 230 V ±10% 50 Hz
Nominal power: 2.5 kW
Nominal current: 11 A
On-site fuse: 16A slow-blow
Heat emission (air-cooled chambers):
Klodpfx Aszgr U Rsb Iow
Max. heat emission to environment: 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally approved refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Amendments and errors in the technical data and specifications reserved!)
For further questions, please contact us by phone.
Annoncen er blevet oversat automatisk. Oversættelsesfejl kan forekomme.
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Du kan også være interesseret i disse annoncer.
Annoncer
Eichenzell
644 km
Fræsemaskine
isel GermanyiCV 4030EC
isel GermanyiCV 4030EC
Annoncer
Eislingen/Fils
843 km
Vertikalt roterende slibecenter
EMAGVLC 100 GT
EMAGVLC 100 GT
Annoncer
Bydgoszcz
653 km
AFBALANCERINGSMASKINE
CIMATCMT-50VSTR
CIMATCMT-50VSTR
Annoncer
Dieren
519 km
Afbalanceringsmaskine, 2 niveauer.
CEMBVPECS 30
CEMBVPECS 30
Annoncer
Odesa
1.821 km
Vertikal afbalanceringsmaskine
97V10 (10kg)
97V10 (10kg)
Annoncer
Contamine-sur-Arve
1.149 km
Lodret cnc automatisk drejebænk
INDEXV100
INDEXV100
Annoncer
Borken
520 km
Klimatestkammer med luftfugtighed
CTSCS-70/350 350 Liter -70°C /+180°C
CTSCS-70/350 350 Liter -70°C /+180°C
Annoncer
Eindhoven
598 km
Klimaattestkammer
Vötsch/WeissGTTS 220
Vötsch/WeissGTTS 220
Annoncer
Wymysłów
739 km
Vötsch VT 7004 – klimakammer / temperaturkammer
Vötsch VT 7004 – komora klimatyczna / komora temperaturowaVötsch VT 7004 – komora klimatyczna / komora temperaturowa
Vötsch VT 7004 – komora klimatyczna / komora temperaturowaVötsch VT 7004 – komora klimatyczna / komora temperaturowa
Annoncer
Borken
520 km
Klimatestkammer med luftfugtighed
VötschVC³ 4100 990 Liter -42°C bis +180°C
VötschVC³ 4100 990 Liter -42°C bis +180°C
Din annonce er blevet slettet
Der opstod en fejl











































































































