Klimatisk testskåp 1300 liter med luftfugtighedKlimakammer 1300 liter med fugtighedsreguleringVötsch
VCS 7130-15 -70°C bis +180°C
Klimatisk testskåp 1300 liter med luftfugtighedKlimakammer 1300 liter med fugtighedsregulering
Vötsch
VCS 7130-15 -70°C bis +180°C
Betingelse
Brugt
Beliggenhed
Borken 

Vis billeder
Vis kort
Oplysninger om maskinen
- Maskinbeskrivelse:
- Klimatisk testskåp 1300 liter med luftfugtighedKlimakammer 1300 liter med fugtighedsregulering
- Fabrikant:
- Vötsch
- Betingelse:
- god (brugt)
Pris og placering
- Beliggenhed:
- Einsteinstraße 8a, 46325 Borken, DE
Ring
Detaljer om tilbuddet
- Noterings-id:
- A19437121
- Referencenr.:
- 24666
- Sidst opdateret:
- d. 20.08.2025
Beskrivelse
Vötsch
Model: VCS 7130-15
Guedpfxjwvgwbo Aateh
Vötsch Climate Test Chamber, Water-Cooled
Specifications for Temperature Tests:
Temperature range: -70°C to 180°C
Temporal temperature deviation at the center of the usable space: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Rate of temperature change:
Heating: 16 K/min
Cooling: 14.5 K/min
Specifications for Climate Tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % RH
Temporal temperature deviation at the center of the usable space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation in the center of the usable space: ±1 to ±3 % RH
Heat compensation: max. 8000 W
Housing dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The chamber is equipped with feedthroughs on the right and left sides, allowing cables and test equipment to be routed into the test chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber lighting:
Halogen bulb 24 V, 50 W
3/N/PE AC 400 V ±10% 50 Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Site fuse: 100 A slow-blow
Max. heat output to the environment: 2.2 kW
Permissible test specimen weight:
Total load of shelf supports: 100 kg
Test chamber floor: 150 kg, Insert shelf: 50 kg
Refrigerant: R 404A / R 23
Weight: 1900 kg
Important safety information for buyers:
The following actions are performed on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and error!)
If you have further questions, we will be happy to answer them by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Model: VCS 7130-15
Guedpfxjwvgwbo Aateh
Vötsch Climate Test Chamber, Water-Cooled
Specifications for Temperature Tests:
Temperature range: -70°C to 180°C
Temporal temperature deviation at the center of the usable space: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Rate of temperature change:
Heating: 16 K/min
Cooling: 14.5 K/min
Specifications for Climate Tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % RH
Temporal temperature deviation at the center of the usable space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation in the center of the usable space: ±1 to ±3 % RH
Heat compensation: max. 8000 W
Housing dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The chamber is equipped with feedthroughs on the right and left sides, allowing cables and test equipment to be routed into the test chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber lighting:
Halogen bulb 24 V, 50 W
3/N/PE AC 400 V ±10% 50 Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Site fuse: 100 A slow-blow
Max. heat output to the environment: 2.2 kW
Permissible test specimen weight:
Total load of shelf supports: 100 kg
Test chamber floor: 150 kg, Insert shelf: 50 kg
Refrigerant: R 404A / R 23
Weight: 1900 kg
Important safety information for buyers:
The following actions are performed on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and error!)
If you have further questions, we will be happy to answer them by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Udbyder
Bemærk: Registrer dig gratis eller log ind, for at få adgang til alle oplysninger.
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Din annonce er blevet slettet
Der opstod en fejl