Klimatisk testkammer -70°C til +180°CVötsch
VCS 7034-5 - 335 Liter
Klimatisk testkammer -70°C til +180°C
Vötsch
VCS 7034-5 - 335 Liter
Betingelse
Brugt
Beliggenhed
Borken 

Vis billeder
Vis kort
Oplysninger om maskinen
- Maskinbeskrivelse:
- Klimatisk testkammer -70°C til +180°C
- Fabrikant:
- Vötsch
- Model:
- VCS 7034-5 - 335 Liter
- Betingelse:
- brugt
Pris og placering
- Beliggenhed:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring
Detaljer om tilbuddet
- Noterings-id:
- A17414103
- Referencenr.:
- 24368
- Sidst opdateret:
- d. 26.06.2025
Beskrivelse
Vötsch
Type: VCS 7034-5
Climatic Test Chamber, Water-Cooled
Test chamber volume: 335 litres
Specifications for temperature testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Rbjdpfx Aeuxq T Dja Dot
Specifications for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions (W x D x H): 580 mm x 765 mm x 750 mm
External dimensions (W x D x H): 870 mm x 1595 mm x 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R-404A / R-23
Important information for you as a buyer!
The following points are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to technical modifications and errors, all information is non-binding!)
Further questions can gladly be answered by telephone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Type: VCS 7034-5
Climatic Test Chamber, Water-Cooled
Test chamber volume: 335 litres
Specifications for temperature testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Rbjdpfx Aeuxq T Dja Dot
Specifications for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions (W x D x H): 580 mm x 765 mm x 750 mm
External dimensions (W x D x H): 870 mm x 1595 mm x 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R-404A / R-23
Important information for you as a buyer!
The following points are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to technical modifications and errors, all information is non-binding!)
Further questions can gladly be answered by telephone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Udbyder
Bemærk: Registrer dig gratis eller log ind, for at få adgang til alle oplysninger.
Registreret siden: 2012
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Du kan også være interesseret i disse annoncer.
Lille annonce
Butzbach
651 km
Bearbejdningscenter
Starrag-HeckertHEC500D
Starrag-HeckertHEC500D
Lille annonce
Wetzlar
639 km
Målesystem
HexagonHexagon Absolut Arm RA8 V2
HexagonHexagon Absolut Arm RA8 V2
Lille annonce
Ruhla
599 km
5-akset fræser
Deckel MahoDMU 70 eVlin
Deckel MahoDMU 70 eVlin
Lille annonce
Tatabánya
1.145 km
Overfladeslibemaskine Overfladeslibning
JungHF 50 (2338)
JungHF 50 (2338)
Lille annonce
Denkendorf
826 km
Målearm med optisk målesystem
Cimcore / perceptronInfinite 5030SC / ScanWorks V4
Cimcore / perceptronInfinite 5030SC / ScanWorks V4
Lille annonce
Borken
520 km
Temperaturprøvelokale 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Lille annonce
Wilbertoord
568 km
Bearbejdningscenter - lodret
DMGDMU 40 Mono Block
DMGDMU 40 Mono Block
Lille annonce
Borken
520 km
Kammer til korrosionsprøvning
VLMSAL 400 V.713.062.000
VLMSAL 400 V.713.062.000
Lille annonce
Malsch
825 km
Planslibemaskine - horisontal
ELB-SchliffSWN 8 ND
ELB-SchliffSWN 8 ND
Lille annonce
Borken
520 km
Klimaprøvelokale
Feutron3702/06
Feutron3702/06
Din annonce er blevet slettet
Der opstod en fejl