Beskrivelse
Vötsch
Type: VC 7018
Vötsch Climate Test Chamber VC 7018 Water-Cooled
Control unit: »Touch Panel«
All control and operation commands can be initiated on the »Touch Panel« simply by touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation for the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on both the right and left sides, allowing measuring lines and test equipment to be routed into the test area.
Feedthroughs included in the standard configuration:
R1: Internal diameter 125 mm
L1: Internal diameter 50 mm
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Enclosure Dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
time stability: ±0.1 to ±0.5 K
spatial stability: ±0.5 to ±2.0 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 4 K/min
Cooling: 2.3 K/min
Specifications for Climate Testing:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% rH
temperature deviation (time, center of test area): ± 0.1 to ± 0.3 K
temperature deviation (spatial): ± 0.5 to ± 1.0 K
temperature gradient: 1 to 2 K
humidity deviation (time, center of test area): ± 1 to ± 3 % rH
Electrical Connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, to be provided by customer
Refrigerant: R-404A and R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg net
Important safety information for you as the buyer!
Iedpjwh Ttmsfx Agueih
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data and information subject to change and error!)
For further questions, we are happy to assist you by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Type: VC 7018
Vötsch Climate Test Chamber VC 7018 Water-Cooled
Control unit: »Touch Panel«
All control and operation commands can be initiated on the »Touch Panel« simply by touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation for the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on both the right and left sides, allowing measuring lines and test equipment to be routed into the test area.
Feedthroughs included in the standard configuration:
R1: Internal diameter 125 mm
L1: Internal diameter 50 mm
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Enclosure Dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
time stability: ±0.1 to ±0.5 K
spatial stability: ±0.5 to ±2.0 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 4 K/min
Cooling: 2.3 K/min
Specifications for Climate Testing:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% rH
temperature deviation (time, center of test area): ± 0.1 to ± 0.3 K
temperature deviation (spatial): ± 0.5 to ± 1.0 K
temperature gradient: 1 to 2 K
humidity deviation (time, center of test area): ± 1 to ± 3 % rH
Electrical Connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, to be provided by customer
Refrigerant: R-404A and R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg net
Important safety information for you as the buyer!
Iedpjwh Ttmsfx Agueih
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data and information subject to change and error!)
For further questions, we are happy to assist you by phone.
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Udbyder
Bemærk: Registrer dig gratis eller log ind, for at få adgang til alle oplysninger.
Send anmodning
Telefon & Fax
+49 2861 ... annoncer
Du kan også være interesseret i disse annoncer.
lille annonce

520 km
Klimatestkammer med luftfugtighed 190 liter
VötschVC 7018 -70 bis 180°C
VötschVC 7018 -70 bis 180°C
Din annonce er blevet slettet
Der opstod en fejl