GBS test impulse generator rev3 for long-term insulation testing
The Prüfpuls system is designed for long-term insulation testing of test specimens with a capacitance of up to 6 nF.
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200Hz.
· Pulse-width modulation 16-24kHz of the sine wave via full-bridge.
· Converter voltage adjustable from 0-600V, Imax=2.6A, maximum output 1.3kW
· Pulse current limitation: 110A (cut-off threshold)
Pulse transformer – control
· Full-bridge control
· Full-bridge power supply adjustable 0-1000V, max. 1.3A
· Pulse current limitation: 100A (cut-off threshold)
· Pulse width 20-120μs, nominal 94μs, adjustable
· 2 selectable series inductances: 150μH, 300μH, to adapt pulse width and rise times to the load capacitance and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Selectable positive, negative, or alternating depending on sine signal polarity.
· Cosine pulse at transformer output
Pulse transformer cascade
· Output transformers in 5-stage cascaded configuration.
· Overall transformation ratio selectable via taps: 1:7.7, 1:10 or 1:15.
· Maximum output voltage 15kV for possible load capacitances of: * 6nF with a pulse width of 73μs and a repetition frequency of 2.5kHz * 10nF with a pulse width of 103μs and a repetition frequency of 1.25kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23kV via parallel spark gaps
· Thermistor for overtemperature detection in the first transformer stage.
· Ground-side current measuring socket 100 mV/A.
Qgqsbmp2
Breakdown detection, testing
· If the maximum bridge currents for the transformer control or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable hour meter to record test duration.
Ksdpju Egz Rofx Af Nswt
Manufacturer price approx. €59,500
More items – new and used – can be found in our shop!
International shipping costs on request!
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
The Prüfpuls system is designed for long-term insulation testing of test specimens with a capacitance of up to 6 nF.
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200Hz.
· Pulse-width modulation 16-24kHz of the sine wave via full-bridge.
· Converter voltage adjustable from 0-600V, Imax=2.6A, maximum output 1.3kW
· Pulse current limitation: 110A (cut-off threshold)
Pulse transformer – control
· Full-bridge control
· Full-bridge power supply adjustable 0-1000V, max. 1.3A
· Pulse current limitation: 100A (cut-off threshold)
· Pulse width 20-120μs, nominal 94μs, adjustable
· 2 selectable series inductances: 150μH, 300μH, to adapt pulse width and rise times to the load capacitance and voltage.
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Selectable positive, negative, or alternating depending on sine signal polarity.
· Cosine pulse at transformer output
Pulse transformer cascade
· Output transformers in 5-stage cascaded configuration.
· Overall transformation ratio selectable via taps: 1:7.7, 1:10 or 1:15.
· Maximum output voltage 15kV for possible load capacitances of: * 6nF with a pulse width of 73μs and a repetition frequency of 2.5kHz * 10nF with a pulse width of 103μs and a repetition frequency of 1.25kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23kV via parallel spark gaps
· Thermistor for overtemperature detection in the first transformer stage.
· Ground-side current measuring socket 100 mV/A.
Qgqsbmp2
Breakdown detection, testing
· If the maximum bridge currents for the transformer control or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable hour meter to record test duration.
Ksdpju Egz Rofx Af Nswt
Manufacturer price approx. €59,500
More items – new and used – can be found in our shop!
International shipping costs on request!
Annoncen blev oversat automatisk, og der kan forekomme nogle oversættelsesfejl.
Udbyder
Bemærk: Registrer dig gratis eller log ind, for at få adgang til alle oplysninger.
Registreret siden: 2008
Send anmodning
Telefon & Fax
+49 2862 ... annoncer
Du kan også være interesseret i disse annoncer.
Lille annonce
Kolbuszowa
1.055 km
Plastforarbejdningsmaskine
Koltex Plastic Recycling SystemsXR 8
Koltex Plastic Recycling SystemsXR 8
Lille annonce
Düngenheim
685 km
Elektrisk wirehejs 5t, højhastigheds
Abus KransystemeGM2000.5000 H-322.41.9000.3E 130.20
Abus KransystemeGM2000.5000 H-322.41.9000.3E 130.20
Lille annonce
Soerendonk
610 km
Gear / gearkasse
Flender / SiemensK2S-2,5
Flender / SiemensK2S-2,5
Lille annonce
Wiefelstede
347 km
Bænkskruestik 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Lille annonce
Tönisvorst
583 km
Ramme 28427
mitlaufendSPH 150 mm
mitlaufendSPH 150 mm
Din annonce er blevet slettet
Der opstod en fejl